Analytical Applications
The
following links are to PDF files and require the
Adobe
Acrobat Reader.
- ARIAS 500 Guidelines of Operation
- Recommendations on setting up your ARIAS 500 Refractometer for the most consistent end results.
- Custom Scales Available
- Reichert has been the leader in refractometry for nearly a century. Over this time period we have developed and collected many scales relating refractive index to properties of interest. To learn more, click on the above link.
- IQ/OQ/PQ
- Installation, Operation, and Performance Qualification is a necessity to ensure proper refractometer measurements.
- IQ/OQ/PQ for Bilirubinometer
- Installation, Operation, and Performance Qualification is necessary to ensure proper bilirubin measurements.
- Refractometer Selection Guide
- Ever wonder what refractometer is right for your application. The following guide will walk you through selecting the perfect refractometer for your needs.
- MARK II Electrical Contact Cleaning
- The following article describes in detail the cleaning of the internal electrical contacts to resolve issues of the reading value continually scrolling.
- Bilirubinometer Control Cuvettes Validation
- The Calibration, High, and Low Level Check Cuvettes used with the UNISTAT BILIRUBINOMETER degrade over time. Reichert recommends you send these in annually for reclassification.
- Refractometer Maintenance Guide
- Based upon decades of customer feeback, Reichert is pleased to offer the following guidelines to help maintain your refractometer in optimal operating condition.
- Serial Port Communications
- The bench-top refractometers offered by Reichert are capable of downloading data to, and receiving commands from a computer via the serial port.
- Calibration - What is it?
- What is calibration and why is it important to verify the calibration of a refractometer?
- Converting Refractometer Readings to Actual Concentration
- Refractometers may be used to test many types of liquid samples. Though they are designed with a scale that is particular to one specific product, they are versatile enough for use in any application where a concentration reading is desired.
- Brix Conversion Table
- Download the correlation table for Sucrose (Brix) versus Refractive Index.
- Jaundice on the Rise
- With Jaundice (Hyperbilirubinemia) on the rise, clinicians need a fast, accurate method for determining neonatal total bilirubin levels. The Reichert UNISTAT Bilirubinometer has been proven the most accurate and reliable.
- Surface Plasmon Refractometer
- The SR7000 is used to measure BSA/Anti-BSA Kinetics in a typical binding study utilizing surface plasmon refractometry.
- Industrial Fluid Tester Saves Money, Improves Quality
- Improving quality and saving money on tooling is as simple as using the Leica Industrial Fluid Testers to monitor machining fluid concentration level. Automatic Temperature Compensation ensures accurate readings, which results in up to 35% reduced tooling
- AOAC Method For Ethanol Content Measurement
- The AOAC has developed a method for measurement of ethanol content in a distilled liquor sample utilizing a refractometer. To find out more, simply download the following.
- Calibration Testing/Verification
- Verifying the reading accuracy of a refractometer is as simple as following these instructions.
- Measuring Plastics with an Abbe Refractometer
- Following is a method used for measuring transparent solid materials such as plastics on a traditional Abbe type refractometer.
- Official Methods List for Refractometers
- Attached is a reference list of just some of the official methods which have been developed for refractometers.
- Temperature Coefficient Calculation and Temperature Correction
- Temperature is a critical component of a refractometer measurement. As temperature increases, refractive index decreases. To correct for this so that readings can be accurately compared, the temperature coefficient of the sample must be determined.
|
|